BSYB SERIES | |
15W Wall Mount Switching Power Supplies. | |
Description | |
The BSYB series of AC/DC switching mode power supplies provide 15 Watts of continuous output power.All supplies are UL 94V-0 min compliant, include a 2 prong plug-in mains connector for certain applications. All models All models meet FCC class B and are designed to comply with UL/c-UL requirements. All units are 100% burned in and tested. | |
Features: | |
|
Electrical Characteristics:
Sym . | Param eter | Test Conditions | Min. | Typ. | Max. | Unit |
Vin | Input Voltage | Operating Voltage | 90 | 264 | VAC | |
fin | Input Frequency | 47 | 63 | Hz | ||
Po | Output Power Range | Vin=90 to 264VAC | 0 | 15 | W | |
Vo | Output Voltage Range | 4.5 | 24 | V | ||
Io | Output Current Range | 0.01 | 2.5 | A | ||
Iil | Input Current (Low Line) | Io=Full load, Vin=115VAC | 0.4 | A | ||
Iih | Input Current (High Line) | Io=Full load, Vin=230VAC | 0.3 | A | ||
Irl | Low Line Inrush Current | Io=Full load, 25°c, Cool start, Vin=115VAC | 12 | 15 | A | |
Irh | High Line Inrush Current | Io=Full load, 25°c, Cool start, Vin=230VAC | 16 | 20 | A | |
Eff | Efficiency | Io=Full Load, Vin=230VAC | 71 | 76 | 85 | % |
REG-i | Line Regulation | Io=Full Load | 0.5 | 1 | % | |
REG-o | Load Regulation | Vin=230VAC | 3 | 5 | % | |
OVP | Over Voltage Protection | Nil | % | |||
OCP | Over Current Protection | Nil But,Output protected to short circuit conditions | % | |||
Ttr | Time of Transient Response | Io=Full Load to Half Load, Vin=100VAC | 4 | mS | ||
Thold | Hold-Up Time | Io=Full Load, Vin=100VAC | 5 | 10 | mS | |
Ts | Start Up Time | Io=Full Load, Vin=100VAC | 2 | 3 | S | |
Vrn | Ripple & Noise(Peak to Peak) | Full Load, Vin=90VAC | 0.5 | 1 | % | |
Ilk | Safety Ground Leakage Current | Io=Full Load, Vin=240VAC | 0.2 | 0.25 | mA | |
Pno | No-Load Power Consumption | No load,Vin=240VAC | 0.2 | 0.3 | W | |
Environmental :
Sym . | Param eter | Test Conditions | Min. | Typ. | Max. | Unit |
Toper | Operating Temperature | 0 | 70 |
C | ||
Tstg | Storage Temperature | -40 | 85 |
C | ||
Hr | Relative Humidity | No-Condensing | 5 | 95 | % | |
MTBF | Operating Temperature at 25 C, Calculated per MIL-HDBK-217F | 0.1M | Hrs | |||
Pd | Derate linearly from 100% load at 40 C to 50% load at 70 C |
Safety Specifications:
Sym . | Param eter | Test Conditions | Min. | Typ. | Max. | Unit |
Vps | Dielectric Withstanding Voltage for Primary to secondary | Primary to secondary | 4242 | VDC | ||
CISPR | EMI requirements for CISPR-22 | Vin=220VAC | B | CLASS | ||
FCC | EMI requirements for FCC PART-15 | Vin=110VAC | B | CLASS |
Output Voltage And Current Rating Chart ( Single Output ):
Model Num ber. | Output Voltage | Max. Output Current | Total Regulation | Max. Output Watts |
BSY10-102 | 5 ~ 6 VDC | 1.60 ~ 1.50 A | 5% | 10W |
BSY10-103 | 6 ~ 8 VDC | 1.50 ~ 1.25 A | 5% | 10W |
BSY10-104 | 8 ~ 11 VDC | 1.25 ~ 0.91 A | 5% | 10W |
BSY10-105 | 11 ~ 13 VDC | 0.91 ~ 0.77 A | 5% | 10W |
BSY10-106 | 13 ~ 16 VDC | 0.77 ~ 0.63 A | 5% | 10W |
BSY10-107 | 16 ~ 21 VDC | 0.63 ~ 0.48 A | 3% | 10W |
BSY10-108 | 21 ~ 27 VDC | 0.48 ~ 0.37 A | 3% | 10W |
BSY10-109 | 27 ~ 33 VDC | 0.37 ~ 0.30 A | 3% | 10W |
BSY10-110 | 33 ~ 40 VDC | 0.30 ~ 0.25 A | 3% | 10W |
BSY10-111 | 40 ~ 48 VDC | 0.25 ~ 0.20 A | 3% | 10W |
① The total regulation on model 102~105 is required to use AWG#20 / 4FT output cable. The total regulation on model 106~110 is required to use AWG#24 / 4FT output cable. The regulation and efficiency will be changed by modified output cable. | Note:1. Dimensions are shown in mm. 2. Weight: 90gs approx. 3. Optional output connector: See page Appendix. |